CE ETL 400W 48V open frame power supply SMPS

 Description:

The open frame power supply 400W 48V is the compact size,it is certificated by CE ETL and CCC,the efficiency is more than 90%,it can be used to the stage lights,DC motor and charger.


Features:

1,400W ower supply with High efficiency, low temperature rise;
2,CE power supply 400W with Built-in filters, low output noise;
3,DC48V 400W open frame power supply with Wide range of AC input voltage;
4,400W switching power supply 48V with Short circuit, overload, over-temp. protection;

5,400W Switching powers Used in Ventilator,charger etc.


Parameter
            Item NoK18-UP400S12K18-UP400S24K18-UP400S36K18-UP400S48
Output

Output Voltage

+12V+24V+36V+48V

Rated Current

33.4A16.7A11A8.3A

Current Range

0-33.4A0-16.7A0-11A0-8.3A

Rated Power(with cooling fan)

350W350W350W350W
Rated power(without cooling fan)400W400W400W400W

Ripple

200mVp-p240mVp-p
360mVp-p480mVp-p

Adjustable Output Range

11.4-12.6V

22.8-25.2V34.2-37.8V45.6-50.4V

Output Accuracy

±1%

Line Regulation

±0.5%

Load Regulation

±0.5%

Set up,Rise,Keep up time

500ms, 50ms, 20ms/230VAC

Input

Input Voltage Range

88~264V AC,100~370VDC

Input Current

6A/115V,3A/230V

Input Frequency

47~63Hz

Efficiency

90%93%93%93%

Inrush Current

15A@115VAC,30A@230VAC

Leakage Current

<3.5mA@240V

Protection

Over Load Protection

110~200%,Hiccup,automatic recovery

Over temp. Protection

when TS1 position>105 degree,it will be protected,then automatic recovery.

Environment


Working Temp.,Humidity

-20~60℃,10~90% RH,No condensation

Storage Temp.,Humidity

-20~85℃,10~95% RH

Temp.,Drift

±0.03%/℃(0~50℃)

Vibration

10~500Hz, 2G 10min /1cycle, PERIOD FOR 60min EACH AXES

Safety&EMC Standards


Safety Standards

GB4943,EN60950 EN62368

Withstand Voltage

I/P-O/P:3kv,I/P-FG:1.5KV,O/P-FG:0.5KV DC 1min

Insulation Resistance

I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms

EMC Standards

EN55015 CLASSB;EN61000-3-2

OthersDimension

127*82*39mm(L*W*H)

Weight0.6kg
Notes

1.All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity;

2. Accuracy: includes set up tolerance, line regulation, load regulation and so on;

3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end;

4. Line regulation: at rated load conditions, the input voltage changes from low to high measured;

5. Load regulation: the measured output load from 0 to 100% load change measured.